User's Manual

Table Of Contents
Accessories 6 - 13
Battery Charging
Main Battery Charging
The TC8000 Charging/Scan LED indicates the status of the battery charging in the device. See Table 1-3 on page
1-6.
The 6,400 mAh battery fully charges in less than six hours at room temperature.
Spare Battery Charging
Each Battery Charging LED indicates the status of the battery charging in each slot. The table below describes the
Battery Charging LED status.
The 6400 mAh battery fully charges in less than six hours at room temperature.
Charging Temperature
Charge batteries in temperatures from 0 °C to 40 °C (32 °F to 104 °F). The battery charger always performs battery
charging in a safe and intelligent manner. At higher temperatures (e.g. approximately +37 °C (+98 °F)) the battery
charger may for small periods of time alternately enable and disable battery charging to keep the battery at
acceptable temperatures. The battery charger indicates when charging is disabled due to abnormal temperatures
via its LED.
Establishing Ethernet Communication
1. Touch .
2. Touch Ethernet.
3. Slide the Ethernet switch to the ON position.
Table 6-5 Battery Charging Indicators
State Indication
Off Battery is not charging. It is not inserted correctly in the cradle or connected to a
power source. Charge is not powered.
Solid Amber Battery is charging.
Solid Green Charge complete.
Fast Blinking Red
(2 blinks/second)
Charging error, e.g.:
- Temperature is too low or too high.
- Charging has gone on too long without completion (typically eight hours).
Solid Red Battery is at end of useful life.
NOTE
Refer to the TC8000 Integrator Guide for information on configuring the Ethernet settings.