User's Guide

7
most sensitive setting. Typing the character gon the terminals keyboard will place the user in
this mode.
Figure 8 - Terminal Screen after Executing 'g' Menu Item
Aiming the Unit
For best results, the unit should be aimed so that the white-faced plastic front is perpendicular to
the line-of-sight between the unit and the target.
Chapter 3 ADVANCED MENU OPTIONS
There are seven other advanced options available to the user if a custom software interface is to
be used.
DAC Menu Item
The DAC Menu is the menu that allows the user to change sensitivity levels on the SPIDER-
650s internal DAC (digital-to-analog converter). If the user wishes to change one of the 5 bias
voltage values, he/she must first enter the vkey followed by the number corresponding to the
appropriate run number. For example, if the user wants to change the bias value for the third
transceiver run, a vwill be typed. This will bring up the following display:
select run number 1-5 , d = display voltages , q=end
enter voltage as 2 digit hex
Then the user hits the 3key and will see:
V3= 0x
show up on the terminal to indicate that the DAC value for the third run should be entered. This
is prompting the user to enter a 2 digit hex value between 0x00 and 0xFF. Only values after the
xshould be entered.