Print > Sensors > Manual Calibration
Calibrate the printer to adjust the sensitivity of the media and ribbon sensors.
Print > Sensors > Label Sensor
Set the sensitivity of the label sensor.
Important This value is set during sensor calibration. Do not change these
settings unless you are told to do so by Zebra Technical Support or by an
authorized service technician.
Print > Sensors > Sensor Type
Select the media sensor that is appropriate for the media that you are using. The
reflective sensor typically is used only for black mark media. The transmissive
sensor typically is used for other media types.
Related ZPL command(s): ~JC
SGD command used:
ezpl.manual_calibration
Control panel key(s): Hold
PAUSE + FEED + CANCEL for 2 seconds to
initiate calibration.
Printer web page: The calibration procedure cannot be initiated
through the web pages. See the following web
page for settings that are set during sensor
calibration:
View and Modify Printer Settings > Calibration
Important • Do not change these settings
unless you are told to do so by Zebra
Technical Support or by an authorized
service technician.
Accepted values: 0 to 255
SGD command used:
ezpl.label_sensor
Printer web page: View and Modify Printer Settings > Calibration
Accepted values: TRANSMISSIVE
REFLECTIVE
Related ZPL command(s):
^JS
SGD command used:
device.sensor_select
Printer web page: View and Modify Printer Settings > Media Setup