Configuration
Configuration and Calibration LCD Displays
R4Mplus User Guide 65
FORMAT CONVERT
Format Convert
The Format Convert setting is used when upgrading from a printer of
lower resolution to a printer of higher resolution and the user does not
wish to modify their formats.
Example: If your original formats were written for a 150 dpi printer and
your new printer is 300 dpi, you would choose150-300.
Default: None
Selections: None, 150–300, 150–600, 200–600, 300–600
1. Press SELECT to select the parameter.
2. Press PLUS (+) or MINUS (–) to display other choices.
3. Press SELECT to accept any changes and deselect the parameter.
IDLE DISPLAY
Idle Display
If RTC is installed, this parameter selects the LCD options for the
real-time clock.
Default: FW Version
Selections: FW Version, MM/DD/YY 24HR, MM/DD/YY 12HR,
DD/MM/YY 24HR, DD/MM/YY 12HR
1. Press SELECT to select the parameter.
2. Press PLUS (+) or MINUS (–) to display other choices.
3. Press SELECT to accept any changes and deselect the parameter.
RTC DATE
RTC Date
If RTC is installed, this parameter allows changing of the date.
1. Press SELECT to select the parameter.
2. Press PLUS (+) to increase the value of the selected digit.
3. Press MINUS (–) to move to the next digit.
4. Press SELECT to accept any changes and deselect the parameter.
RTC TIME
RTC Time
If RTC is installed, this parameter allows changing of time.
1. Press SELECT to select the parameter.
2. Press PLUS (+) to increase the value of the selected digit.
3. Press MINUS (–) to move to the next digit.
4. Press SELECT to accept any changes and deselect the parameter.
Table 7 • Printer Parameters and Other LCD Displays (Sheet 17 of 20)
Parameter/LCD Display Action/Explanation