Configuration
Configuration and Calibration LCD Displays
R110/R170XiIIIPlus User Guide 69
MEDIA POWER UP Media Power Up
This parameter sets the action of the labels when the printer is turned on.
• Press the right or left oval to display the choices.
Default: Calibration
Selections: Feed, Calibration, Length, and No Motion
• Feed—feeds the labels to the first registration point.
• Calibration—determines the length of the label.
• Length—used in continuous mode to feed the last stored label length.
• No Motion—the media does not move. You must press FEED to cause the
printer to resynch to the start of the next label.
HEAD CLOSE Head Close
This parameter sets the action of the labels when the printhead is closed.
• Press the right or left oval to display the choices.
Default: Calibration
Selections: Feed, Calibration, Length, and No Motion
• Feed—feeds the labels to the first registration point.
• Calibration—determines the length of the label.
• Length—used in continuous mode to feed the last stored label length.
• No Motion—the media does not move. You must press FEED to cause the
printer to resynch to the start of the next label.
Table 1• Front Panel LCD Messages (Page 13 of 19)
LCD Description