User's Manual

Table Of Contents
Printer Operation
Adjust Sensors
R110/R170XiIIIPlus User Guide 33
the peak of the graph up or down to optimize the readings for your application (for
more information, see Sensor Profile on page 63).
When calibration is complete, RELOAD ALL displays.
9. Open the printhead and pull the media forward until a label is positioned under the media
sensor.
10. Reload the ribbon back into to its proper position.
11. Close the printhead.
12. Press the right oval to continue.
The printer does a calibration equivalent to pressing CALIBRATE; during this
process, the printer determines the label length. To see the new readings on the
new scale, print a sensor profile.