User's Manual Part 2

106 R110PAX4 User Guide 58981L-002 Rev. 1 2/11/05
RFID Guidelines
~RO
~RO
Reset Advanced Counters
Description The ~RO command resets the advanced counters used by the printer to monitor
label generation in inches and centimeters, the number of labels printed, and the number of
valid and voided RFID labels. Any single error during programming of an RFID tag will result
in that label being considered “void” by the counter.
Four resettable counters are available. The values for the counters are displayed on the printer
configuration label.
Format
~ROc
This table identifies the parameters for this format:
Parameters Details
c = counter number Accepted Values:
1 (counter 1)
2 (counter 2)
3 (valid RFID label counter)
4 (voided RFID label counter)
Default Value: None. If a value is not specified, the command is ignored.
Example 1 • This example shows how the counter portion of the printer configuration
labels looks when counter 1 is reset by sending
~RO1.
Before
After