User's Manual
Table Of Contents
- Contents
- Preface
- Introduction
- Printer Setup
- Printer Operation
- Front Panel Controls
- RFID Guidelines
- Overview
- Getting Started with RFID
- Creating Basic RFID Label Formats
- RFID Label Format 1-Write a 96-bit Tag in Hexadecimal
- RFID Label Format 2-Write a 64-bit Tag in Hexadecimal
- RFID Label Format 3-Write a 96-bit Tag in ASCII
- RFID Label Format 4-Read Data from Tag and Print on Label
- RFID Label Format 5-Write Tag, Read Tag, and Print Data on Label
- RFID Label Format 6-Write Tag, Read Tag, and Return Results to Host
- ZPL II Commands for RFID
- Data Ports
- Memory Cards
- Routine Maintenance
- Troubleshooting
- Specifications
- Proprietary Statement
- Warranty Information
- Printer Software and Firmware License Agreement
- Index
106 R110Xi/R170Xi User Guide 23063L-003 Rev. A 6/24/05
Data Ports
Serial Port
RS-422/RS-485 Interconnections
An interface adapter (Zebra part number 33114M) is required to connect the printer’s RS-232
DB-9 interface to a host computer through an RS-422 or RS-485 interface. A generic DB-25
adapter can be used. Figure 38 shows the cable wiring for interconnecting the DB-9 to the
interface adapter’s DB-25 female connector.
Figure 38 • DB-9 to DB-25 Connections
Caution • A qualified service technician must install a jumper on the printer’s main logic
board at JP1, pins 2 and 3, for the RS-422/RS-485 interface adapter to function properly.
Female DB-25 Connector on
RS-422/RS-485 Adapter
Data input B (–)
Data input A (+)
Data output B (–)
Data output A (+)
Frame ground
Signal ground ref.
+5 VDC 725 mA source
1
9
11
13
14
16
19
NOTE: Pins 2–8, 10, 12, 15, 17, 18, and 20–25 are unused and unterminated.