RFID Guidelines
^RW
23063L-003 Rev. A 6/24/05 R110Xi/R170Xi User Guide 93
^RW
Set RFID Read and Write Power Levels
Description This command sets the read and write power levels. This function is useful
when using different tag types or transponders that require different power levels to obtain the
best read and write abilities.
Format ^RWr,w
This table identifies the parameters for this format:
Parameters Details
r = read power
Sets the power level to match the desired output as calibrated in the factory.
Accepted Values: H (high), M (medium), or L (low)
Default Value: H
w = write power
Sets the power level to match the desired output as calibrated in the factory.
Accepted Values: H (high), M (medium), or L (low)
Default Value: H