Register 0x06: RANGE
Bit Type Function Default
Bit 7 R/W RANGE[7] 0
Bit 6 R/W RANGE[6] 0
Bit 5 R/W RANGE[5] 0
Bit 4 R/W RANGE[4] 0
Bit 3 R/W RANGE[3] 0
Bit 2 R/W RANGE[2] 0
Bit 1 R/W RANGE[1] 0
Bit 0 R/W RANGE[0] 0
RANGE[7:0]
This register sets the beginning range in 512 feet intervals where the unit will
start to sample the return energy. A value of 0x00 means that the unit will
look at objects from 1 – 256 feet. A value of 0x01 is for the range of 513 –
769 feet, and so forth for higher values. Although valid values for this register
are from 0x00 to 0xFF, the maximum range is highly dependant on transmitter
power, antenna gain, and receiver sensitivity.