Register 0x03: RF_CONTROL
Bit Type Function Default
Bit 7 R/W RX_ENABLE 0
Bit 6 RESERVED 0
Bit 5 RESERVED 0
Bit 4 RESERVED 0
Bit 3 RESERVED 0
Bit 2 RESERVED 0
Bit 1 RESERVED 0
Bit 0 R/W CNTRL_REG_RESET 0
CNTRL_REG_RESET
This bit resets the digital control registers when set high. All registers will
reset to their default values. Any active radar operation will terminate as well.
RX_ENABLE
This bit controls the switched power supply on the RF receiver board – “high”
to turn on, “low” to turn off. During normal operation, the RF receiver gets
switched on automatically during detection and switched off thereafter. This is
to conserve battery life. This bit should be left in the default off value.