The charger is designed so a DC power cable can be installed from the rear of the charger housing without removing the base.
The cable and connector do not interfere with the base lying flat on any surface. The DC cord snakes through strain relief
features in the housing to prevent accidental disconnects. The external power adapter DC cable terminates with a right-angle
connector at the charger interface.
Figure 2-28 MPACT-MB6000-CHRGR - DC Power
2.12.1 Battery Charging Guidelines
Failure to follow these guidelines may result in fire, explosion or other hazard.
The area in which the units are charged should be clear of debris and combustible materials or chemicals. Particular care
should be taken when charging in a non commercial environment.
To charge the battery, the battery and charger temperatures must be between 0 - 40 degrees Celsius.
Voltage 5Vdc +/- 5%
Current Each Badge requires 900 mA during charging, total 5Vdc power is 10 Amps
Power Consumption 50-60 Watts
Power Supply External 12 Vdc, 5 Amps max, 60 watts total, enclosed power supply
Power Cord AC power cord connecting external power supply to AC power
Power Supply
Connector
Barrel connector (2.5mm outside diameter). The plastic enclosure has built-in strain relief
to prevent accidental disconnects.
Power Indicator All Badges within the charger platform have LEDs indicating charging state
Temperature 0 to 40 degrees C (operating), -40 to 70 degrees C (storage)
Humidity 5 to 95% RH (operating) 85% RH (storage)