User's Manual
Table Of Contents
- Product Introduction
- Infrastructure Device Installation
- Device Configuration
- License Information
- Customer Service
- Certification and Safety Information
- FCC Regulatory Information
- Safety Information for the MOTOMESH Products
- Safety Certification
- Regulatory Requirements and Legal Notices
- Regulatory Requirements for CEPT Member States (www.cept.org
- European Union Notification
- Equipment Disposal
- UK Notification
- Belgium Notification
- Luxembourg Notification
- Czech Republic Notification
- Norway Notification
- Greece Notification
- DECLARATION OF CONFORMITY
- EU Declaration of Conformity for RoHS Compliance
- CMM Labeling and Disclosure Table
- Software License Terms and Conditions
MOTOMESH DUO 2.0 4300 Users Guide
November 2007
2-11
Procedure 2-4 Assembling a European or Australian AC Power MOTOMESH Duo Device
Assembling a DC Power MOTOMESH Duo Device
Use the following procedure to assemble a MOTOMESH Duo Device with DC power.
Procedure 2-5 Assembling a US or European/Australian DC Power MOTOMESH Duo Device
Device Connectivity Testing
Only after
a MiSC has been setup on the network, and an infrastructure device has been added using
the MeshManager, element management system software, that the procedure below can be used to
verify connectivity to a device.
Procedure 2-6 Testing Infrastructure Device Connectivity
1
Place the brackets at the desired position on the pole.
2
Adjust the position of the box so that the antenna connecters are positioned vertically. Align the antennas
with the N-type connectors on the box and rotate to close.
3
Insert the cable into the external Ethernet port and tighten the connector to ensure a weatherproof seal.
4
Insert the Power Plug into the 3-pin connector.
Note: For detailed wiring instructions, see the separate European or Australian Wiring instructions,
generally provided with the cable and power connector.
1
Place the brackets at the desired position on the pole.
2
Adjust the position of the box so that the antenna connecters are positioned vertically. Align the antennas
with the N-type connectors on the box and rotate to close.
3
Insert the cable into the external Ethernet port and tighten the connector to ensure a weatherproof seal.
4
Identify a certified LPS power supply capable of 10.8-14VDC. Using the custom power cable provided,
connect the Red wire to power and the White wire to ground. If a power source chassis ground is
available, connect the Green wire to the chassis ground.
Important Note: If the cable has 4 wires, (Black/White/Red/Green), Black is not connected. If the cable
has 3 wires, (Red/Black/Green), connect RED to Power, Black to Ground and Green to Chassis.
1
Apply power to the device, the device should be operation in 60 to 120 seconds
2
Obtain the 802.11 MAC addresses for the device subcomponents that were recorded in the MAC Address
Table earlier in this manual. The address will be in the following format: xx-xx-xx-xx-xx-xx.
3
Within the Device Manager screen, right-click on the appropriate IAP or MWR device in the Device Tree
and select the Ping Device option.
4
Check for a successful response to the Ping command in the Named Device results dialog box. A
successful response to the ping commands verifies connectivity to the device (IAP or MWR).
5
Repeat steps 1-4 for additional IAP or MWR devices.