Earth Ground Locations.
Bolt Size 8mm. Max
Length 25mm.
6 INSTALLATION AND MOUNTING
Read Installation and Instruction sheet included with the Location Sensor as
well as all Safety and Installation Warnings/Cautions before installing. Follow
the Site Design document for installed location.
6.1 Safety and Installation Warnings and Cautions
Warning - Warning - Electrical Shock: A protective earthing
conductor with green and yellow insulation, minimum of 18 AWG, shall be
installed to the protective earthing terminal of the metal enclosure when I/O or
power cables are routed outdoors. National electrical codes shall be followed
to install facility protective earthing conductor to the protective earthing
terminal.
Figure 3 Safety and
Warnings
Warning - Electrical Shock: No operator serviceable parts inside. Refer
servicing to qualified personnel. To prevent electrical shock, do not remove
covers.
Caution - The Location Sensor hardware must be installed by a qualified
service technician
Caution - Use of Zebra external power supply is limited to indoor use
and a max 40° C environment. Only use Zebra approved power supplies.
Caution - The Timing Sync cable use is limited to indoor only.