User Manual

___________________________________________________________________________
WhereLAN III User’s Guide
___________________________________________________________________________ 34
User’s Guide, WhereLAN III draft D1675 rev F
© Copyright Zebra Technologies, 2012
Zebra Confidential
There are three ways to fix these issues.
1. The best is to have the customer site upgrade to VSS 4.0.5.2 or later,
which has the tools and system builder that take care of the issues
directly.
2. The next best is to see if the customer will allow new tools to be
loaded onto their system, if they require an approval time for full VSS.
The tools will be the System Builder and iSensor from the VSS 4.0.5.2
release. This will work with legacy version of VSS.
a. With this the MAC of the WhereLAN-III can be entered
accurately (as it is shown on the WHERELAN-III label) into
system builder, in the Location Sensor, WLN3 of the tree view.
Under the ‘Site Attributes’ tab, make sure the 4.0.5.2 VSS
Compatibility box is unchecked for legacy VSS systems. This
will save and publish the sitedata.dat in the correct form.