User's Manual

___________________________________________________________________________
WhereLAN III User’s Guide
___________________________________________________________________________ 27
User’s Guide, WHERELAN III D1675 rev A
© Copyright ZES, 2010
Zebra Confidential
Confirm that the site Location Sensor channel assignment is correct by
running “display locate” from the LP Manager tool with a tag placed
directly under each LS. Verify that the nearest Location Sensor, as
indicated by a “0” in the display locate report, is that Location Sensor
nearest the tag.
Verify that detects are received on the channel by using either LP
Manager Detect History, or WTLPHealth LS detects when a tag is
placed at a distance from each Location Antenna equivalent to the
maximum required range from that Location Antenna. Typical tag to
Location Antenna range is 1000 ft (305 m) (Unobstructed/ outdoor),
350 ft (107 m) Minimally Obstructed (indoor office/ light
commercial), 250 feet (76 m) Significantly Obstructed (heavy
industrial).
Section Signoff
Initial Date Comments/ Exceptions