8.2 Timing Cable Pinout
This Cat5 two pair cable should be constructed with straight through wiring,
with pin 1 on one end routed to pin 1 on the other end. For the 2 pair CAT5
cable, the following pin out must be used (Figure 612). See WhereLAN III
Installation Guide D1677 for full install details, and use of CAT-5 for Timing
Cables.
Pair 1: orange/white wire is pin 1; orange wire is pin 2
Pair 2: white/blue wire is pin 3; blue wire is pin 4
Figure 6 Timing cable wiring pin out
For a reliable system operation, the jacket
of the timing cable must be
securely crimped inside the RJ-22 (4p4c) connector. It is recommended 2
pair cable be utilized to ensure a proper crimp. If a 2 pair cable is not
available Standard eight conductor Cat 5 cable may be used, but the steps
in Installation Guide D1677 must be followed.
RJ22
2 Pair Cat5
To pin 1 white/orange
To Pin 2 orange
To pin 3 white/blue
To pin 4 blue
____________
Note
____________