Hyperterminal via Serial Port
Communication Parameters:
• Null-modem cable, 9-pin female to 9-pin female
• 19200 baud
• 8 data bits, 1 stop bit, no parity, no hardware flow control
Hyperterminal is used in only two instances. The first is for initial
configuration in which the Location Sensor has been configured for DHCP
but there is no DHCP server available. The second instance is if a fault occurs
during the first stage of the boot process, or if visibility to the boot process is
needed for debugging installation problems.
5.3 Location Sensor MAC/ IP Address Configuration
Location Sensors communicate over an Ethernet interface using TCP/IP. For
the LOS-5000-00AB, both the Location Sensor and the embedded Client Card
must be independently configured with their own unique IP addresses. The IP
address of each LS must be recorded and entered into the ZES site file, which
contains the configuration information for each LS, including its location, and
MAC address.
Failure to configure the Location Sensor prior to operation may result in
an inoperative unit.
Each Location Sensor is shipped with a label set containing one label (Figure
1) with the bar coded MAC address of the Location Sensor and Wifi Client