Do not attempt to communicate with the Location Sensor until it has
completed the first stage of the boot process (i.e., left LED is solid). Doing
so will stop the boot process. The unit must be reset to clear this
condition.
These units are configured using:
• Telnet/SSH via Ethernet (preferred)
• iSensor (Sensor Analyzer)
• WhereWand
• Hyperterminal (or any terminal emulation software) via serial port
Telnet/SSH is the preferred method of communicating with the Location
Sensor, once installed. Use the HyperTerminal is for initial set-up before
being installed on a network for setting static Ip addresses, if DHCP is not
used.
Telnet via Ethernet
Communication Parameters:
• 10/100 Mb/s
• Cat 5 cable/ RJ-45 plug To connect via telnet, open a DOS command
prompt window and type telnet <IP address>,where the IP address is