Configuration options when LLRP in the reader is in Client mode:
Reconnect to the server – Enable to attempt reconnection to the specified server if the connection is lost.
Disable to not attempt reconnection if the connection is lost.
Server IP – Configures the IP address of the server.
Client Port – Configures the LLRP host port to connect to. Default is 5084.
Connect Status – Indicates whether or not the reader is connected to the LLRP host. This button toggles
between ConnectLLRP and DisconnectLLRP. Click ConnectLLRP to initiate an LLRP connection to the
host server.
To select the LLRP Client mode, check the LLRP Client Mode check box. This uses LLRPClient IP and
LLRPClient/Server Port values to connect to the client.
When operating in LLRP server mode, incoming requests from the client use only the LLRP Port value as the
listening port. After setting the parameters, they persist across reader reboots.
Use the Connect LLRP/Disconnect LLRP button to immediately connect and disconnect LLRP from host.
Table 4-2
LLRP Communication Configuration Options
Setting Description Possible Values
LLRP Status Displays the current state of the LLRP server on the reader.
Indicates whether or not the LLRP is running.
Running
Not Running
Operation Mode Sets the LLPR mode in the reader. Server
Client
Client Port Configures the LLRP listening port on the reader. The default is
5084.
Connect Status Indicates the LLRP client connect status as connected or
disconnected. Click the button to toggle between connected or
disconnected status. This button is grayed out if there is no client
connected.
ConnectLLRP
DisconnectLLRP
NOTE The web console parameters that affect LLRP are:
Region Control
Enable/disable antenna check
Monostatic configuration using advanced read point configuration page
Enable/disabled state of a read point class