User's Manual
Table Of Contents
- IBM Interface
- Wand Emulation Interface
- Scanner Emulation Interface
- 123Scan2
- OCR Programming
- Introduction
- OCR Parameter Defaults
- OCR Programming Parameters
- Enable/Disable OCR-A
- OCR-A Variant
- Enable/Disable OCR-B
- OCR-B Variant
- Enable/Disable MICR E13B
- Enable/Disable US Currency Serial Number
- OCR Orientation
- OCR Lines
- OCR Minimum Characters
- OCR Maximum Characters
- OCR Security Level
- OCR Subset
- OCR Quiet Zone
- OCR Bright Illumination
- OCR Template
- OCR Check Digit Modulus
- OCR Check Digit Multiplier
- OCR Check Digit Validation
- Symbologies
- Introduction
- Scanning Sequence Examples
- Errors While Scanning
- Symbology Parameter Defaults
- UPC/EAN
- Enable/Disable UPC-A
- Enable/Disable UPC-E
- Enable/Disable UPC-E1
- Enable/Disable EAN-8/JAN-8
- Enable/Disable EAN-13/JAN-13
- Enable/Disable Bookland EAN
- Decode UPC/EAN/JAN Supplementals
- User-Programmable Supplementals
- UPC/EAN/JAN Supplemental Redundancy
- UPC/EAN/JAN Supplemental AIM ID Format
- Transmit UPC-A Check Digit
- Transmit UPC-E Check Digit
- Transmit UPC-E1 Check Digit
- UPC-A Preamble
- UPC-E Preamble
- UPC-E1 Preamble
- Convert UPC-E to UPC-A
- Convert UPC-E1 to UPC-A
- EAN-8/JAN-8 Extend
- Bookland ISBN Format
- UCC Coupon Extended Code
- ISSN EAN
- Code 128
- Code 39
- Code 93
- Code 11
- Interleaved 2 of 5 (ITF)
- Discrete 2 of 5 (DTF)
- Codabar (NW - 7)
- MSI
- Chinese 2 of 5
- Matrix 2 of 5
- Korean 3 of 5
- Inverse 1D
- Postal Codes
- GS1 DataBar
- Composite
- 2D Symbologies
- Redundancy Level
- Security Level
- Report Version
- Macro PDF Features
- Advanced Data Formatting
13 - 16 Symbol DS6878 Product Reference Guide
OCR Template
Parameter # F1 23h
This option creates a template for precisely matching scanned OCR characters to a desired input format. Carefully
constructing an OCR template eliminates scanning errors.
To set or modify the OCR decode template, scan the OCR Template bar code, then bar codes corresponding to
numbers and letters on the following pages to form the template expression. Then scan
End of Message in Chapter
15, Advanced Data Formatting. The default is
54R which accepts any character OCR strings.
Required Digit (9)
Only a numeric character is allowed in this position.
Template Valid data Valid data Invalid data
99999 12987 30517 123AB
Required Alpha (A)
Only an alpha character is allowed in this position.
Template Valid data Valid data Invalid data
AAA ABC WXY 12F
OCR Template