Maintenance, Troubleshooting & Technical Specifications 3 - 3
Beeper Indications
Digital Scanner emits low/high/low
beeps.
ADF transmit error. See Chapter 15, Advanced Data
Formatting for information about ADF
programming.
Invalid ADF rule is detected. See Chapter 15, Advanced Data
Formatting for information about ADF
programming.
The Code 39 buffer was erased or
there was an attempt to clear or
transmit an empty buffer.
Normal when scanning the Code 39
Buffering
Clear Buffer
bar code or
upon attempt to transmit an empty
Code 39 buffer.
Digital Scanner emits a
low/high/low/high beep sequence
while it is being programmed.
Out of ADF parameter storage
space.
Erase all rules and re-program with
shorter rules.
Digital Scanner emits long low/long
high beeps.
Input error, incorrect bar code or
Cancel
bar code was scanned.
Scan the correct numeric bar codes
within range for the parameter
programmed.
Page timeout; remote device is
out of range/not powered.
Move the digital scanner back into
range of the remote device; try to
re-connect; check remote device
configuration.
Digital Scanner emits long low/long
high/long low/long high beeps.
Out of host parameter storage
space.
Scan
Default Parameters on page
5-4
.
Out of memory for ADF rules. Reduce the number of ADF rules or the
number of steps in the ADF rules.
Connection attempt was rejected
by remote device.
Free up remote device resources.
Digital Scanner emits
high/high/high/low beeps.
RS-232 receive error. Normal during host reset. Otherwise,
set the digital scanner's RS-232 parity
to match the host setting.
Table 3-1
Troubleshooting (Continued)
Problem Possible Causes Possible Solutions