User's Manual

Quick Reference Guide 9
Lost Connection to Host
If scanned data does not transmit to the cradle’s host, ensure that all cables are
firmly inserted and the power supply is connected to an appropriate AC outlet, if
applicable.
If scanned data still does not transmit to the host, reestablish a
connection with the host:
1. Disconnect the host interface cable from the cradle.
2. Wait three seconds.
3. Reconnect the host interface cable to the cradle.
4. Reestablish pairing with the cradle by scanning the pairing bar code.
Charging the Digital Scanner Battery
When using a new battery in the digital scanner, the battery requires a charge to
be enabled. Insert the battery in the digital scanner and place the digital scanner
in the cradle (see
Inserting the Digital Scanner in the Cradle on page 8). The
battery begins charging when the cradle LED indicator starts flashing amber. The
battery is fully charged when the cradle LED is solid green. A complete charge of
a fully discharged battery can take up to three hours using external power and up
to ten hours using the USB interface cable.
Cradle LED Indicators
LED Indication
Standard Use
Green (stays on) Power Up
Radio Indications
Green (off, then on) Bluetooth connection established
Blue Page button
Blue (fast/fast/slow)
Page issued
Battery Indications
Amber (stays on) Pre-charging
Amber blinking Charging
Green (stays on) Fully charged
Amber fast blinking Charging Error
Battery End of Life Indications
Red blinking Charging
Red (stays on) Fully charged
Red fast blinking Charging error