Data Sheet

M5S digital output - „BO“/“PO“
For control of relays, lamps, buzzers or other
signaling devices
Relay, solid state relay, or transistor output
Galvanic isolation
M5S-BOT0x075C1B
Description Internal circuit
Isolation
External circuit
Signal Voltage/current Signal Voltage/current
Optocouple with
transistor output
0-20 kHz 3-6 V DC/5 mA Yes 0-5 kHz, sink 3-30 V/750 mA DC
INT+
INT-S
EXT-S
EXT-
U
+ -
U
INT
3 V-6 V
U
EXT
3-30 V
max. 750 mA
M5S-BOT0x075-C1B
U
- +
1
2 3 4
5
6
7
8
M5S-BOS0x080C1B
Description Internal circuit
Isolation
External circuit
Signal Voltage/current Signal Voltage/current
Optocouple with SSR
output
0-5 kHz 3-6 V DC/5 mA Yes 50-60 Hz, AC 20-250 V/0.8 A AC
INT+
INT-S
EXT-S
EXT-
U
+ -
U
INT
3 V-6 V
U
EXT
20-250 V AC
max. 0,8 A
M5S-BOS0x080-E2B
U
1
2 3 4
5
6
7
8
Page 3 of 10 www.tde-instruments.de