Installation Instructions

SP230/SP230-S5 2x2 PtP/PtMP 802.11ac Wave 2 Access Point QSG
58-140007-IQN _V1.0 Page 1
Package Contents
One access point One clamp Two waterproof cable glands
One ground wire One mounting bracket
+ Four screws
Note: SP230 and SP230-S5 both provides two waterproof cable glands.
Installation Requirements
TERMS OF USE: All Ethernet cabling runs must use CAT5e, 24 AWG (or above) Shielded Twisted
Pair (STP) cabling. In addition, please cut the cable into a proper length, strip the cables on both
ends, and crimp the wires into RJ45 connectors. It is the professional installer’s responsibility to
follow local country regulations, including operation within legal frequency channels, output power,
indoor cabling requirements, and Dynamic Frequency Selection (DFS) requirements.
Mounting the Access Point on the Pole
Attach the mounting bracket to the device
using four screws (included in the packaging).
Securely tighten the screws.
Attach the clamp to encircle pole and the
mounting bracket. Securely tighten the clamp.
Note: Please avoid having obstacles or metal plates surround the access point.