Technical Speci cations
PCS Frequency CEL Frequency
Frequency 1850 - 1990 MHz 824 - 894 MHz
System Gain 62 dB 65 dB
Band Supported ALL: A,D,B,E,F & C ALL: A,B, A’ & B’
Output power UL: +20 dBm; DL: +10 dBm UL: +20 dBm; DL: +10 dBm
Cable Loss
3000 MHz RG-6, approx. 1dB/10 ft. 3000 MHz RG-6, approx. 0.6 dB/10 ft.
Network Format CDMA, GSM, TDMA, GPRS, EDGE, EVDO, HSPA, 3G
Base Unit RF Connectors F-type female and TNC female
Wall Supply Unit 100-240 VAC 50 Hz - 60 Hz
Input and Output Impedance TNC Connector: 50 Ohm; F Connector: 75 Ohm
Power Consumption 3W standby; 7W max signal - 2.0A Max
System Certi cations
UL, FCC Parts 15 & 24 (PCS), FCC Parts 15 & 22 (CEL), Industry Canada
Base Unit Size and Weight 5” x 7” x 1.25” - 12 oz.
Base Unit and Power Supply Indoor Use Only, 0° to 45° C (32° to 113° F)
The Manufacturer’s rated output power of this equipment is for single carrier operation. For situations when multiple
carrier signals are present, the rating would have to be reduced by 3.5 dB, especially where the output signal is re-
radiated and can cause interference to adjacent band users. This power reduction is to be by means of input power
or gain reduction and not by an attenuator at the output of the device.
Solid GREEN Normal condition at power up.
Slowly Alternating RED and GREEN zBoost is working, but at reduced
performance and coverage due to “non-
ideal” setup.
Solution: Increase the distance
between External Antenna and
Indoor Antenna to achieve maximum
performance and coverage.
Fast Flashing RED
Indicates insu cient distance between
the External Antenna and the Indoor
Antenna.  e ampli er is operating at
signi cantly reduced coverage.
Solution: Increase space between
Indoor and External antennas.
Solid RED
System is receiving signals from either
the mobile device or the base station
transceiver which are too strong for
proper operation.
Solutions: Move away from
receiving antenna with your cell phone.
Move antenna away from other
devices..
Fast Alternating RED and GREEN
followed by no light
e ampli er is disabled.
Solution: Unplug and start over.
At Initial Power Up Only
Solid GREEN Normal condition.
Solid RED
System is receiving signals from either
the mobile device or the base station
transceiver which are too strong for
proper operation.
Solution: Please unplug your system.
Re-orient your External Antenna and/
or Base Unit to reduce the excessive
signal source. Plug your system back in.
If still solid red, call customer support
1-800-871-1612.
After Initial Power Up