User's Manual

zBOOST
®
YX545 SOHO USER GUIDE
12
zBOOST
®
YX545 SOHO USER GUIDE
13
Solid GREEN Normal condition at power up.
Slowly Alternating RED and GREEN
zBoost is working, but at reduced
performance and coverage due to
“non-ideal” setup.
Solution: Increase the distance
between antenna and ampli󰘰er to
achieve maximum performance and
coverage.
Fast Flashing RED Indicates insu󰘲cient distance between
the antenna and the ampli󰘰er. The
ampli󰘰er is operating at signi󰘰cantly
reduced coverage.
Solution: Increase space between
base unit and antenna.
Solid RED
System is receiving signals from either
the mobile device or the base station
transceiver which are too strong for
proper operation.
Solutions: Move away from
receiving antenna with your cell
phone. Move antenna away from
other devices..
Fast Alternating RED and GREEN
followed by no light
The ampli󰘰er is disabled.
Solution: Unplug and start over.
zBoost® Base Unit Light Indicators
At Initial Power Up Only
Solid GREEN
Normal condition.
Solid RED
System is receiving signals from either
the mobile device or the base station
transceiver which are too strong for
proper operation.
Solution: Please unplug your system.
Re-orient your Signal Antenna and/
or Base Unit to reduce the excessive
signal source. Plug your system
back in. If still solid red, call customer
support 1-800-871-1612.
After Initial Power Up
Technical Specications
Product Specications for zBoost® YX545 SOHO – Dual Band
PCS band
Frequency Uplink: 1850 to 1910 MHz
Downlink: 1930 to 1990 MHz
System Gain 60dB
PCS band supported A, D, B, E, F, C
Networks CDMA, GSM, GPRS, EDGE, EVDO, 1xRTT,
UMTS, HSPA, 3G
Cellular band
Frequency Uplink: 824 to 849 MHz
Downlink: 869 to 894 MHz
System Gain 60dB
CEL band supported A, B, A’, B
Networks CDMA, GSM, GPRS, EDGE, EVDO, 1xRTT,
UMTS, HSPA, 3G
General
Power Consumption Power Supply Current 3W standby; 7W max signal - 5.0VDC, 2.0A Max
Wall Supply Input ; Voltage 100-240VAC, 50-60 Hz
Output Power +20 in UL and +13 in DL
Input and Output Impedance TNC Connector: 50ohm; F Connector:75 ohm
System Certications FCC Parts 15 & 24 (PCS), Parts 15 & 22 (CEL),
Industry Canada
Base Unit Size and Weight 5” x 7x 1.259 oz.
Operating Conditions Indoor Use Only (4 - 105° F)
This product uses patented technology to protect the carrier network
This product is covered by patent US 7,706,744. Other U.S. and
foreign patents pending.