Specifications

Page 8
IFB Voting Enable
This enables / disables the IFB Voting function.
The purpose of the voting is to allow the ERX to choose and switch to the stronger signal from two
different ZaxNet transmitters. One purpose of this is if you are on a large set you can place a second
transmitter at a different location and the ERX will choose the stronger signal. Just set the second
transmitting frequency a minimum of 2MHz higher than the first unit.
Time Code Output Enable - (ERX-TCD Only)
This allows you to enable /disable time code output from the headphone jack.
OFF- Time code output is disabled.
ON: OUT BOTH Sends time code to both left and right out of the headphone output.
ON: OUT RIGHTSends time code to the right side of the headphone output.
ON: OUT LEFT Sends time code to the left side of the headphone output.
If you send time code out it will override the audio to the selected output - so it is possible to output both
time code and audio simultaneously to a camera.
Time Code Delay - (ERX-TCD Only)
This allows you to adjust the delay of the timecode out of the ERX. The ERX will allow you to either delay
or advance the time code.
Adjustments are from -5.5 frames to 50 frames in 0.5 frame increments.
IFB VOTING:
NORMAL (OFF)
TIMECODE OUTPUT
OFF
TC DELAY
0 (NORMAL)