8. EXPOSURE CONTROLS/PERSONAL PROTECTION
Control parameters
Exposure Guidelines
Chemical Name ACGIH TLV OSHA PEL NIOSH IDLH
Lead
7439-92-1
TWA: 0.05 mg/m
3
TWA: 50 µg/m
3
TWA: 50 µg/m
3
Pb
Action Level: 30 µg/m
3
Poison,
See 29 CFR 1910.1025 Action
Level: 30 µg/m
3
Pb Poison, See
29 CFR 1910.1025
IDLH: 100 mg/m
3
TWA: 0.050 mg/m
3
Sulfuric acid
7664-93-9
TWA: 0.2 mg/m
3
thoracic fraction TWA: 1 mg/m
3
(vacated) TWA: 1 mg/m
3
IDLH: 15 mg/m
3
TWA: 1 mg/m
3
ACGIH TLV: American Conference of Governmental Industrial Hygienists - Threshold Limit Value OSHA PEL: Occupational Safety and Health
Administration - Permissible Exposure Limits NIOSH IDLH Immediately Dangerous to Life or Health
Other Exposure Guidelines
Vacated limits revoked by the Court of Appeals decision in AFL-CIO v. OSHA, 965 F.2d 962
(11th Cir., 1992) See section 15 for national exposure control parameters
Appropriate engineering controls
Engineering Measures
Showers
Eyewash stations
Ventilation systems
Individual protection measures, such as personal protective equipment
Eye/Face Protection
Face protection shield.
Skin and Body Protection
Wear protective gloves and protective clothing. Long sleeved clothing. Chemical resistant
apron. Impervious gloves.
Respiratory Protection
No protective equipment is needed under normal use conditions. If exposure limits are
exceeded or irritation is experienced, ventilation and evacuation may be required.
7. HANDLING AND STORAGE
_____________________________________________________________________________________________
Precautions for safe handling
Handling
In case of rupture: Handle in accordance with good industrial hygiene and safety practice.
Avoid contact with skin, eyes or clothing. In case of insufficient ventilation, wear suitable
respiratory equipment. Use only with adequate ventilation and in closed systems. Do not
eat, drink or smoke when using this product. Take off contaminated clothing and wash
before reuse. Do not breathe dust. Avoid generation of dust.
Conditions for safe storage, including any incompatibilities
Storage
Keep containers tightly closed in a dry, cool and well-ventilated place. Protect from
moisture. Store locked up. Keep out of the reach of children. Store away from other
materials.
Page 6 / 14
Incompatible Products
Acids. Bases. Oxidizing agent.