PARAMETER CHANGE
E MODE N MODE H MODE
ACCELER. DELAY LEVEL = 0 LEVEL = 0 LEVEL = 0
DECELER. DELAY LEVEL = 0 LEVEL = 0 LEVEL = 0
MAX SPEED UP 74 Hz 84 Hz 93 Hz
MIN SPEED UP 18.00 Hz 18.00 Hz 18.00 Hz
CUTBACK SPEED 100% 100% 100%
TILT SPEED 30 Hz 30 Hz 30 Hz
SHIFT SPEED 30 Hz 30 Hz 30 Hz
AUX SPEED 81 Hz 81 Hz 81 Hz
HYD SPEED FINE 30 Hz 30 Hz 30 Hz
MAXIMUM CURRENT LEVEL = 9 LEVEL = 9 LEVEL = 9
IDLE TIME 1,5 1,5 1,5
SET OPTION
HOUR COUNTER KEYON KEYON KEYON
SET TEMPERATURE ANALOG ANALOG ANALOG
JOYSTICK OFF OFF OFF
DIGITAL LIFT OFF OFF OFF
SET MODEL
CONNECTED TO PUMP PUMP PUMP
ADJUSTMENTS
SET BATTERY TYPE 80V 80V 80V
ADJUST BATTERY 82.5 V 82.1 V 82.5 V
THROTTLE 0 ZONE 5% 5% 5%
THROTTLE X POINT 63% 63% 63%
THROTTLE Y POINT 36% 36% 36%
ADJUSTMENT #04 145
145
145
PWM ON MAIN CONT OFF OFF OFF
PWM ON AUX OUT. ON ON ON
MC/AUX PWM 15% 15% 15%
- 22/25/30BHA-7 Pump (05) setup -