Service manual

109
109
- 15/18/20BT-7, 16/18/20B-7 Pump (05) Parameter Setup.
CODE
ADJUSTMENTS
(service level)
Parameter explanation.
248
MIN TILT UP
Tilt up sensor minimum voltage recording.For the elctr-hyd distributor version it can be
adjusted from console/display (press enter).
247
MAX TILT UP
Tilt up sensor maximum voltage recording.For the elctr-hyd distributor version it can
be adjusted from console/display (press enter).
246
MIN TILT DOWN
Tilt down sensor minimum voltage recording.For the elctr-hyd distributor version it can
be adjusted from console/display (press enter).
245
MAX TILT DOWN
Tilt down sensor maximum voltage recording.For the elctr-hyd distributor version it
can be adjusted from console/display (press enter).
244
MIN SHIFT RGT.
Shift right sensor minimum voltage recording.For the elctr-hyd distributor version it
can be adjusted from console/display (press enter).
243
MAX SHIFT RGT.
Shift right sensor maximum voltage recording.For the elctr-hyd distributor version it
can be adjusted from console/display (press enter).
242
MIN SHIFT LFT.
Shift left sensor minimum voltage recording.For the elctr-hyd distributor version it can
be adjusted from console/display (press enter).
241
MAX SHIFT LFT.
Shift left sensor maximum voltage recording.For the elctr-hyd distributor version it can
be adjusted from console/display (press enter).
254
MIN AUX IN
Aux in sensor minimum voltage recording.For the elctr-hyd distributor version it can be
adjusted from console/display (press enter).
253
MAX AUX IN
Aux in sensor maximum voltage recording.For the elctr-hyd distributor version it can
be adjusted from console/display (press enter).
252
MIN AUX OUT
Aux out sensor minimum voltage recording.For the elctr-hyd distributor version it can
be adjusted from console/display (press enter).
251
MAX AUX OUT
Aux out sensor maximum voltage recording.For the elctr-hyd distributor version it can
be adjusted from console/display (press enter).
Values
0.5V
4.5V
4.5V
0.5V
4.5V
0.5V
0.7V
4.5V
0.7V
4.5V
4.5V
0.5V