User manual

RESET function
Press the programme button until the appliance is in programme selection mode.
With this function you can cancel the running programme.
User mode
While the appliance is in programme selection mode:
1. Press and hold the programme button until the indicator flashes, and the indicators and are on.
Settings available in the user mode:
The level of the water softener according to the water hardness.
The activation or the deactivation of the acoustic signal for the end of programme.
The activation or the deactivation of AirDry.
As the appliance stores the saved settings, there is no need to configure it before every cycle.
Adjusting the water softener
1. While the appliance is in user mode, wait until the indicators and are off.
The indicator still flashes.
The current setting is indicated by the number of flashes of the indicator (e.g. 5 flashes + pause + 5
flashes... = level 5).
2. Press the programme button to change the setting. Each pressing of the programme button increases the level
number. After reaching level 10, the count starts again from level 1.
3. Press the on/off button to confirm the setting.
The water hardness table
German degrees
(°dH)
French degrees
(°fH)
mmol/l Clarke degrees Water softener lev-
el
47 -50 84 - 90 8.4 - 9.0 58 - 63 10
43 - 46 76 - 83 7.6 - 8.3 53 - 57 9
37 - 42 65 - 75 6.5 - 7.5 46 - 52 8
29 - 36 51 - 64 5.1 - 6.4 36 - 45 7
23 - 28 40 - 50 4.0 - 5.0 28 - 35 6
19 - 22 33 - 39 3.3 - 3.9 23 - 27
5
1)
15 - 18 26 - 32 2.6 - 3.2 18 - 22 4
11 - 14 19 - 25 1.9 - 2.5 13 - 17 3
4 - 10 7 - 18 0.7 - 1.8 5 - 12 2
<4 <7 <0.7 < 5
1
2)
1) Factory setting
2) Do not use salt at this level.
Activating the acoustic signal for the end of programme
By default, the acoustic signal is deactivated but it is possible to activate it.
6