MOUNTING
1. Disconnect the power supply from the
mains by the phase fuse, the circuit-
breaker or the switch-disconnector
that are joined to the proper circuit.
2. Check if there is no voltage on con-
nection cables by means of a spe-
cial measure equipment.
3. Install ASM-01 device in the switch-
board on TH 35 DIN rail.
4. Connect the cables with the terminals
according to installing diagram.
5. Switch on the power supply from the
mains.
6. Adjust the demanded switch on time
by means of a potentiometer.
DIMENSIONS
GUARANTEE CARD
There is 24 months guarantee on the product
Salesman stamp and signature, date of sale
1. ZAMEL provides a two-year warranty for its products.
2. The ZAMEL warranty does not cover:
a) mechanical defects resulting from transport, loading / unloading or other circumstances,
b) defects resulting from incorrect installation or operation of ZAMEL products,
c) defects resulting from any changes made by CUSTOMERS or third parties, to products sold or equipment necessary
for the correct operation of products sold,
d) defects resulting from force majeure or other aleatory events for which ZAMEL is not liable.
3. All complaints in relation to the warranty must be provided by the CUSTOMER in writing to the retailer after discovering
a defect.
4. ZAMEL will review complaints in accordance with existing regulations.
5. The way a complaint is settled, e.g. replacement of the product, repair or refund, is left to the discretion of ZAMEL.
CONNECTING
FUNCTIONING EXAMPLE OF INSTALLATION
PRODUCT FAMILY
After proper mounting and installa-
tion the device is ready to work. Rele-
asing the system with the monostable
pushbutton causes the lighting to switch
on for the preset time. After the preset
time is over the lighting is automatically
switched off till its another release. The
staircase lighting time delay switch co-
operates with 3-wire or 4-wire system.
While mounting the device pay attention
the release and load systems are pro-
perly connected, otherwise the device
can be irreparably damaged. Because
of no anti-blocking system the light is
constantly switched on in cases the pu-
shbutton is blocked.
RELAY CAPACITY
500 W
2000 W
1000 W
750 W
The staircase lighting time delay switch
ASM-01 belongs to staircase lighting time
delay switches ASx family.
INNER DIAGRAM
TIME COURSE
t
t t
t
t
3 wire system 4 wire system
Typical application:
The staircase lighting time delay switch ASM-01 operating the staircase ligh-
ting works in 3-wire installation. Monostable pushbutton (equipped with illumination)
can be connected parallely.
LN
t
IN
IN
Device
version
Casing version:
M - modular
N - surface
H - hermetic
P - flush junction box Ø60 mm
Device version:
01 - 3- or 4-wire installation
02 - anti-blocking function
03 - anti-blocking function and ON/
AUTO/OFF mode switch
10 - fluent lighting brightening and
dimming
Voltage version:
24V - 24 V AC/DC available for
ASM-02
U - 12÷240 V AC/DC available for
ASH-01, ASM-01, ASN-01