User's Manual

.4.2. LOAD CAPACITY SPECIFICATIONS
The cross regulation defined as follows, the voltage regulation limits DC include DC Output ripple & noise.
LOAD STM. +3.3V +5V +12V1 DC +12V2 DC -12V +5VSB
FULL LOAD MHMMHH 13.4A 21A 7.6A 7.6A 0.5A 2.5A
FULL LOAD HMMMHH 22A 15.4A 7.6A 7.6A 0.5A 2.5A
+3.3V MAX
other MIN
HLLLLL 22A 3A 3A 3A 0A 0A
+5V MAX Other
MIN
LHLLLL 0.5A 15A 1.5A 1.5A 0A 0A
+12V1&+12V2
MAX Other
MIN
LLHHLL 0.5 A 2.0A 10A 15A 0A 0A
-12V MAX other
MIN
LLLLHL 0.5A 0.3A 1A 1A 0.5A 0A
+5VSB MAX
other MIN
LLLLLH 0.5A 0.3A 1A 1A 0A 2A
ALL MIN LLLLLL 0.5A 0.3 A 1A 1A 0A 0A
4.3. HOLD-UP TIME (@FULL LOAD)
115V / 60Hz : 17 mSec. Minimum. 230V / 50Hz : 17 mSec. Minimum.
The output voltage will remain within specification, in the event that the input power is removed or interrupted, for the
duration of one cycle of the input frequency. The interruption may occur at any point in the AC voltage cycle. The
power good signal shall remain high during this test.
4.4.OUTPUT RISE TIME
(10% TO 95% OF FINAL OUTPUT VALUE, @FULL LOAD)
115V-rms or 230V-rms
+ 3.3Vdc : 20ms Maximum
+ 5Vdc : 20ms Maximum
+ 12Vdc : 20ms Maximum
-12Vdc : 20ms Maximum
+ 5Vsb : 25ms Maximum
4.5.OVER VOLTAGE PROTECTION
Voltage Source Protection Point
+3.3V 3.76V-4.8V
+5V 5.6V-7.0V
+12V 13.0V-15.6V