User's Manual

Table. 1 Loading Table for Efficiency Measurements
360W(loading shown in Amps)
Loading +12V1 +12V2 +5V +3.3V -12V +5Vsb
Full 11.0 13.0 9.0 10.0 0.3 2.0
Typical 5.0 9.0 3.0 5.0 0.1 1.0
Light 3.0 3.5 1.0 2.0 0.0 1.0
Table 2. Minimum Efficiency Vs Load
Loading Voltage Full load
Typical
load
Light load
Required Minimum
Efficiency
115V 75% 75% 70%
Required Minimum
Efficiency
230V 80% 80% 75%
3.5 MECHANICAL SPECIFICATIONS
The mechanical drawing of the subject power supply, which indicate the form factor, location of the mounting
holes, location, the length of the connectors, and other physical specifications of the subject power supply. Please
refer to the attachment drawing.
4.0. OUTPUT ELECTRICAL REQUIREMENTS
4.1 OUTPUT VOLTAGE AND CURRENT RATING
Output
MINIMUM
LOAD
NORMAL
LOAD
MAXIMUM
LOAD
LOAD
REG
LINE
REG.
RIPPLE&NOISE RIPPLE
+3.3V 0.5A
11A
22A
±5% ±1%
100mV P-P 50mV P-P
+5V 0.3A
10.5A
21A
±5% ±1%
100mV P-P 50mV P-P
+12V1 1A
5A
11 A
±5% ±1%
200mV P-P 120mV P-P
+12V2 1A
7.5A
15A
±5% ±1%
200mV P-P 120mV P-P
-12V 0A
0.15A
0.5A
±10% ±1%
200mV P-P 120mV P-P
+5VSB 0A
1.25A
2.5A
±5% ±1%
100mV P-P 50mV P-P
( 1 ) +3.3V & +5V total output not exceed 150W.
( 2 ) +3.3V & +5V & +12V1 & +12V2 total output not exceed 347W
( 3 ) total output for this subject power supply is 360 watts
( 4 ) +5VSB Peak current loading is 3A , shall be supported for a minimum of 500m second.