Installation Guide
2630 Townsgate Road  Tel: (805) 446-4460       
Westlake Village, CA 91361  Fax: (805) 446-4455   
 www.zaca-inc.com 
RECESSED MEDICINE CABINET INSTALLATION AND CARE 
I. LOCATION 
  A. All ZACA medicine cabinets are designed for 
recessed installation in a standard wall opening 14” 
wide, 24” or 34” high, and 3½” (or more) deep. 
  B. To replace an existing cabinet, remove old 
cabinet, verify that the wall opening is the correct 
size, and proceed with MOUNTING, step II. 
  C. New installations require the location and fabri-
cation of a suitable wall opening. For applications in 
which a wall opening is impractical, surface mount 
frames are available for purchase from your dealer. 
    1. Select a wall opening site that is centered 
between wall studs that are positioned 16” on center. 
    2. The center of the wall opening is commonly 
located 60” above the floor. Alter this dimension to 
suit individual need or to facilitate clearance between 
the top or bottom of the hinged mirror and obstacles 
such as counter top, faucet, electrical outlet, light fix-
ture, ceiling, etc. 
    3. Mark and cut the 14” wide x 24” or 34” high 
wall opening. Any electrical or plumbing obstructions 
should be removed or relocated by qualified trade 
personnel in strict compliance with all applicable 
building codes. 
II. MOUNTING 
  A. ZACA medicine cabinets are reversible and 
may be installed left or right hand opening. Model 
52-2-34-00 is not reversible. 
  B. Place the cabinet in the wall opening with the 
top of the cabinet body return flange held fully 
against the wall. Noting that the mounting system 
positions the mounting screws at a comfortable 15° 
angle, install two screws (provided) in the UPPER 
mounting holes. Use only the screws provided (do 
not use nails). Do not fully tighten the screw 
heads into the nests at this time; leave approxi-
mately ¼” of thread exposed. Note: Marking and 
drilling .078” diameter pilot holes (at the 15° angle) 
into the studs and/or coating the screw threads with 
soap may reduce the effort of driving the screws. 
  C. Install two screws in the lower mounting holes.  
Again, leave ¼” of the thread exposed. 
  D. Some walls are not flat and plumb. Using a 
carpenter’s level, adjust as necessary to level the 
cabinet as viewed facing the cabinet and viewed 
from the side. Check fit of cabinet door to cabinet 
body flange. Correct any gap between door and 
body by shimming as necessary between the wall 
and the body flange at the corner diagonally opposite 
the gap. (Example: If the gap is top/right, shim bot-
tom/left). Adjust the shim thickness for cross-axis 
alignment to achieve a satisfactory fit between the 
door and body. 
  E. Tighten all four mounting screws until screw 
heads are just seated in their nests. DO NOT 
OVERTIGHTEN! 
III. USEFUL TIPS TO HELP AVOID MIRROR 
SPOILAGE (BLACK EDGE) 
  A. The best and safest cleaner for a mirror is 
clean water used with a soft cloth. 
  B. Never spray anything directly onto a mirror.  
Instead, apply the cleaner to a soft cloth and then 
wipe the mirror. 
  C. Never use any acid, alkali, abrasive or ammo-
nia-based cleaners; they are likely to destroy the mir-
ror and will void the warranty. 
  D. Avoid drips and “puddling” at the mirror edge. 
  E. Thoroughly dry all mirror edges. 
  F. Medicine cabinets should be one of the last 
items installed in new construction to avoid contact 
with solvents, cleaners, etc. 
  G. In humid climates, install mirrors after air 
conditioning is operational. 
  H. Good ventilation will keep mirrors from “sweat-
ing” and creating harmful condensation.
LIMITED WARRANTY (ONE YEAR TERM) 
  Zaca warrants to the original purchaser that it will repair or replace 
without charge products produced by this company shown to have sig-
nificant defects in material or workmanship which are reported to Zaca in 
writing within one (1) year from the date of delivery. 
  The warranty is void in case the product is damaged in transit or if 
the damage or failure is caused by abuse, misuse, abnormal usage, 
faulty installation, damage in an accident, improper maintenance, or any 
repairs other than those authorized by Zaca. At the expiration of the one 
year warranty period, Zaca shall be under no further obligation under any 
warranty, expressed or implied, including the implied warranty of mer-
chantability. This warranty is in place and in lieu of all warranties of mer-
chantability and fitness. 
  Zaca shall not be liable for any consequential damages arising out of 
or in connection with the use or performance of its products. Some 
states do not allow limitations on how long an implied warranty lasts or 
do not allow the exclusion or limitation of incidental or consequential 
damages, so the above limitation may not apply to you. 
  Any liability against Zaca under any implied warranty, including the 
warranty or merchantability, is expressly limited to the terms of this war-
ranty. 
  Permission to return any merchandise under this warranty must be 
authorized by the factory and returned prepaid by the purchaser. 
  Claims under this warranty should be sent directly to Zaca Inc, 2630 
Townsgate Road, Westlake Village, CA 91361.