BL1600 Getting Started s 21
!
Running Dynamic C
Double-click the Dynamic C icon to start the software. Note that the PC
attempts to communicate with the BL1600 each time Dynamic C is
started. No error messages are displayed once communication is estab-
lished.
The communication rate, port, and protocol are all selected by choosing
Serial Options from Dynamic Cs OPTIONS menu.
The BL1600s default communication rate is 19,200 bps. However, the
Dynamic C software shipped by Z-World may be initialized for a different
rate. To begin, adjust the communications rate to 19,200 bps.
Make sure that the PC serial port used to connect the serial cable (COM1
or COM2) is the one selected in the Dynamic C OPTIONS menu. Select
the 1-stop-bit protocol.
See Appendix A, Troubleshooting, if an error message such
as Target Not Responding or Communication Error appears.
Once the necessary changes have been made to establish
communication between the host PC and the BL1600, use the
Dynamic C shortcut <Ctrl Y> to reset the controller and initiate
communication.
$