User`s manual
PK220076 s Specifications
LED
Keypad Conn.
H1
H2
H3
JP4
PLC Bus
Connector
LCD
Interface
JP2 JP3
JP5
JP1
CN1 CN2
21
3
JP6,1
4
Connectors
Only a single, solid conductor should be placed in a screw clamp termi-
nal. Bare copper, particularly if exposed to the air for a long period
before installation, can become oxidized. The oxide can cause a high
resistance (~20 Ω) connection, especially if the clamping pressure is not
sufficient. To avoid this, use tinned wires or clean, shiny copper wire. If
you are using multiple conductors or stranded wire, consider soldering the
wire bundle or using a crimp connector to avoid a loss of contact pressure
to a spontaneous rearrangement of the wire bundle at a latter time.
Soldering may make the wire subject to fatigue failure at the junction with
the solder if there is flexing or vibration.
Header Locations and Jumper Settings
Figure B-5 illustrates the location of the headers on the PK2200.
Table B-4 lists each header and explains possible pin connections.
Figure B-5 PK2200 Jumpers and Headers