User`s manual

XP8000 Series (PLCBus
TM
)
Z-World 530-757-3737 21
Outputs
The XP8100 high-current outputs normally have “sinking” driv-
ers. The sinking drivers (2803s) are rated at a maximum output
of 48V at 500 mA per individual output (when only one output
is active). You can get sourcing drivers (2985s) by special order.
Each driver chip can, and should, be connected to a “K” line to
prevent inductive kickback current from damaging the drivers.
HV[00–31]
U1, U4, U8, U12 U5, U6, U13, U14
2803
K
Addressable
Latches, 8x
High-current
Drivers
Select lines 0–7,
8–15, 16–23, or
24–31
U10A
259
D1
13 9
S0
D2
D3
D0
S1
S2
D
/G
Q[0–7]
GND
10K
+5V
4
When all sinking outputs are on simultaneously, thermal limits
restrict the current to 75 mA per output. If the temperature ex-
ceeds 50°C, derate power dissipation by 55°C per Watt.
Jumpers J1 and J3 route the K and GND lines to the drivers, ac-
cording to whether you have sinking or sourcing drivers.
J1 J3
Sinking Sourcing
0–7
8–15