udpAnalogueInputObject
Type Name Size Offset
unsigned char status 1
0
short value 2
1
short valueLowLimit 2
3
short valueHighLimit 2
5
Total Size of Analogue Input Object
7
udpMessageObject
Type Name Size Offset
unsigned char status 1
0
char message text 64
1
Total Size of UDP Message Object
65
udpDataFrame
Type Name Size Offset
unsigned char packetType 1
0
char deviceId 9
1
unsigned short digitalInputState 2
10
unsigned short systemState 2
12
unsigned short counter 2
14
udpBreakerObject
breakerObjectArray 220
16
udpAnalogueInputObject
analogueInputArray 84
236
udpMessageObject
messageObjectArray 65
320
Total Size of Internal Data frame
384