Document Number: 0848-RPT002 Subsea System User Manual
Author: Graham Cunliffe Page 24 of 27 Revision 1.0
The digital input state has the following format:
The following abbreviations are used in the above bit field description:
FET Ch. - 1 indicates that the FET control signal line is high
7
.
RLY Ch. - 1 indicates that the relay control signal line is high.
FET CP - 1 indicates that the FET clock signal line is high.
RLY CP - 1 indicates that the relay clock signal line is high.
Fault Led - 1 indicates that the SIIM interface board fault LED is ON
8
.
HB Led - 1 indicates that the SIIM interface board “heartbeat” LED is ON
9
.
A.5. Breaker Array
The breaker array consists of ten repeating groups of fields, each breaker being represented
by the following data:
The breaker status has the following format:
7
The FET and RLY channel and clock signal lines are high by default.
8
The fault LED is turned on whenever a breaker is tripped by the sub-sea controller software due to a
breaker limit being exceeded.
9
During normal operation this bit is toggled at 1 Hz.
0
0
0
0
0
0
0
0
0 1 2 3 4 5 6 7
HB
Led
Fault
Led
1
1
RLT
CP
FET
CP
RLY
Ch.
FET
Ch.
8 9 10 11 12 13 14 15
Status
Unsigned integer
2 bytes
Peak
Current
Value
Signed integer
2 bytes
Current Value
Signed integer
2 bytes
Current Limit
Signed integer
2 bytes
Current Timeout
Signed integer
2 bytes
Voltage Value
Signed integer
2 bytes
Voltage Low Limit
Signed integer
2 bytes
Voltage High Limit
Signed integer
2 bytes
Ground Fault Value
Signed integer
2 bytes
Ground Fault Low Limit
Signed integer
2 bytes
Ground Fault High Limit
Signed integer
2 bytes