User Manual
When the door/window state changed, the device will automatically
send a report to the nodes in the group 1.
Notification Report (V4)
Notification Type: Access Control (0x06)
Event: Door/Window is open (0x16)
Door/Window is closed (0x17)
* Tamper Report:
Both the 2 tamper keys are pressed over 2 seconds. The device will
into the alarm state. In that state, if any one of the tamper keys be
released, the device will automatically send a report to the nodes in
the group 1.
Notification Report (V4)
Notification Type: Home Security (0x07)
Event: Tampering. Product covering removed (0x03)
Power Up Procedure
* Battery Power Check
When the device power up, the device will detect the power level of the
battery immediately. If the power level is too low, the LED will continue
flash about 5 seconds. Please change another new battery.
* NWI
When the device power on, the device will check is it already adding to
the network? If doesn't, it will auto start the NWI mode. The LED will
flash in every second and continue 120 seconds. Until timeout or the
device successful to inclusion by controller. The use can presses the
button once to abort the NWI mode.
* Wake
When the device power on, the device will wake about 20 seconds. In
this duration, the controller can communicate with the device. Normally
the device is always sleeping to save the battery energy.
Security Network
The device support the security function. When the device included
with a security controller, the device will auto switch to the security
mode. In the security mode, the follow commands need using Security
CC wrapped to communicate, otherwise it will not response.
Note: A “Security Enabled Z-Wave Controller” must be used in order to
fully utilize this function.
COMMAND_CLASS_BATTERY
COMMAND_CLASS_NOTIFICATION_V4
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_WAKE_UP_V2
Operation Mode
There are two modes “Test” and “Normal”. “Test Mode” is for the user
test the sensor function when installation. “Normal Mode” is for the
normal operation.
Operation Mode can be switched by pressing tamper key three times.
LED can indicate which mode it is. Lighting on one second means
entering test mode, flashing once means entering normal mode.
When the event triggered, normally the LED won't indicated, unless the
battery is in the low level, the LED will flash once. But in the “Test
Mode” the LED also will light ON one second.
When the event triggered, the device will report the messages to the
nodes in the group 1.
Choosing a Suitable Location
1. The recommended mounting height is 160cm
4