Instructions
5
Meters
The meter dialog lists all devices of the network providing (accumulating) meter information. Device name and id, the
type of the meter, the actual meter value and the meter scale is listed. The Date/time column indicates when the given
sensor value was received. It’s possible to call for a meter update but bear in mind that battery operated device will only
respond after the next wakeup. Clicking on the table heads reorders the table view of the data.
Thermostats
The thermostat dialog lists all thermostat devices of the network. Device name and id and the current set point
temperature is shown. The Date/time column indicates when the given set point temperature was transferred to the
device. The set point temperature can be changed using the ‘+’ or ‘-‘ buttons or the slider. Clicking on the table heads
reorders the table view of the data.
Attention: The temperature value does not differentiate between heating and cooling devices. If a cooling and a heating
function shall have different set points please refer to the expert command section for more precise command settings.
Door Locks
The door lock dialog lists all door lock devices of the network. Device name and id, the current status of the lock and last