Instructions

15
The controller is a special node in the network but still a node. Therefore buttons allow accessing the device specific data
of the controller and issue a Node Information Frame. A third button gives access to the controller specific data. Most of
these data is only relevant to developers.
The last block shows the availability of the function calls on the serial API between the Z-Wave transceiver and Z-Way.
‘Not implemented’ means that Z-Way is either not knowing about the function indicated by the function ID or does not
make any use of it. A red function call id or name indicated that Z-Way is able to use this function but the transceivers
firmware did not report to offer this service.
Z-Wave Terms
The following Z-Wave terms are used in this manual:
Static controller is a Z-Wave device with capabilities to manage the network available on a
fixed location in the home
Secure environment: For sensitive applications like door lock control Z-.Wave offers an enhanced encryption
wrapping defined in the command class Security.
Controller Replication: Copy the information of one controller to another controller
SIS: The central database of nodes and ids.
Primary Controller: If no SIS is present one controller becomes the primary controller only able to include
new devices
Secondary Controller: If no SIS is present, all other controllers than the primary controller are called
secondary
Inclusion:
the process of bringing new Z-Wave devices into a network
Exclusion:
the process of removing Z-Wave devices from the network
Association
is a control relationship between a controlling device and a controlled device
Association Group is the list of devices controller by association
SwitchMultilevel, SwitchBinary and Basic are certain command classes
Node Information Frame is a special wireless message issued by a Z-Wave device to announce its
capabilities and functions.
Command Classes Controlled/Supported:
Alarm V2 Controlled, Alarm Sensor V1 Controlled , All Switch V1 Controlled, Application Status V1 Supported, Association V2 Supported and
Controlled, Association Group Information V1 Supported and Controlled, Basic V1 Supported + Controlled, Battery V1 Controlled, Binary
Sensor V2 Controlled, Binary Switch V1 Controlled, Central Scene V1 Controlled, Climate Control V1, Controlled, Clock V1 Supported and
Controlled, Configuration V1 Controlled, CRC16 V1 Supported + Controlled, Device Reset Supported + Controlled, Door Lock V1 Controlled,
Door Lock Logging V1 Controlled, Firmware Update V1 Controlled, Indicator V1 Controlled, Manufacturer Specific V1 Supported + Controlled,
Meter V3 Controlled, Meter Table V1 Controlled, Multichannel V3 Controlled, Multichannel Association V2 Controlled, Multicommand V1
Controlled, Multilevel Sensor V6 Controlled, Multilevel Switch V3 Controlled + Supported, Node Naming V1 Controlled + Supported,
Powerlevel V1 Supported + Controlled, Protection V2 Controlled, Scene Activation V1 Supported + Controlled, Scene Actuator Conf V1
Controlled, Scene Controller Conf V1 Controlled, Security V1 Supported and Controlled, Sensor Configuration V1 Controlled, Thermostat Fan
Mode V3 Controlled, Thermostat Fan State V3 Controlled, Thermostats Mode V3 Controlled, Thermostat Operating State V1 Controlled,
Thermostat Setpoint V3 Controlled, Time V2 Supported + Controlled, Time Parameter V1 Controlled, User Code V1 Controlled, Version V2
Supported + Controlled, Wakeup V2 Controlled, Z-WavePlus V1 Supported + Controlled