User Manual ZX3 : ZX Series Server Rugged Rack Mounted Workstations & Servers for deployed applications Z Microsystems, Inc. · 9820 Summers Ridge Road, San Diego, CA 92121 · T: 858.831.7000 · F: 858.831.7001 · www.zmicro.
REGULATORY Regulatory Information WARNING TO PREVENT FIRE OR SHOCK HAZARDS, DO NOT EXPOSE THIS UNIT TO RAIN OR MOISTURE. ALSO, DO NOT USE THIS UNIT’S POLARIZED AC PLUG WITH AN EXTENSION CORD RECEPTACLE OR OTHER OUTLETS UNLESS ALL THREE PRONGS CAN BE FULLY INSERTED 1. Use the power and video cables supplied with the product to help prevent interference with radio and television reception. The use of cables and adapters may cause interference with electronic equipment in the vicinity of this unit. 2.
TABLE OF CONTENTS Table of Contents Section Page 1.0 Product Overview............................................................................................................................................................ 4 1.1 About This Manual.............................................................................................................................................. 4 1.2 Product Overview...............................................................................................
Product Overview 1.0 Product overview SAFETY PRECAUTIONS This section will provide information and assistance with the following topics: • About This Manual DANGER: To avoid shock hazard: • Product Overview • Do not remove the covers around the ZX3 Server. 1.1 About This Manual This product manual will help you through the installation, setup, and operation of your ZX3 Server.
Product Overview 1.2 Product Description ZX3 Server The ZX3 Station is a high performance, rack mountable, computing and graphics processing powerhouse. At only 5.20” (3U) high by 20 inches deep, this compact, rugged workstation utilizes minimal rack space and delivers an extremely flexible computing and high-capacity storage solution that is unbeatable in mission–ready applications.
SETUP 2.0 SETUP This section will provide information and assistance with the following topics: • ZX3 Shipping Contents WARNING Using assembly hardware that does not match specifications may damage internal components. • ZX3 Cable Connections Outline • Power Supply Options 2.1 Shipment Contents Ensure all of the following parts are included in the package received from Z Microsystems. Verify that no parts have not been damaged during shipment.
FRONT ISO VIEW SETUP 2.3 ZX3 Connections Guide Preparations Required Cables/Connectors In preparation to setting up and connecting the ZX3, turn off the electrical power to your computer. • Power Supply Cable (AC or DC option) • Video Signal Cable (DVI, BNC) • Serial I/O Connector (USB Type B-A) Shown here are standard customer examples. 2.84 GROUNDING STUD MOUSE PORT ADD ON PCI SLOTS AC/DC POWER CONNECTORS 0 .75 17.00 8.75 PRINTER PORT MOUNTING HO (SLIDE RAILS NOT IN 20.
COnfigurations 3.0 Configuring your ZX3 station This section will provide information and assistance with the following topics: • Updating ZX3 modules and configurations • Removing/Re-installing Lockable Face Plate Cover • Removing/Re-installing ZX3 Top Cover • Changing/Re-installing a PCI card Preparations Required Tools In preparation to any configurations change to the ZX3, turn off the electrical power to the ZX3 serve and your computer.
COnfigurations 3.3 REMOVING/INSTALLING MEMORY dimm 4. Install the new Memor y DIMM by carefully aligning the Memor y DIMM parallel to the slot and then gently but firmly inserting. 5. Carefully push the Memory DIMM in using your thumbs. 6. Secure the Memory DIMM by pulling the locking latches towards the Memory DIMM. 3.4 Changing or re-installing a pci card 1. Using a Philips screwdriver, remove the attachment screw for the selected placeholder plate. 2. Remove the plate from the unit casing. 3.
COnfigurations 3.5 replacing a fan 1. If there is a red light on the front panel then a fan needs to be replaced 2. Using a Philips screwdriver, Remove the three screws from the air flow baffle. 7. Lift and remove fan unit from fan assembly. 3. Lif t and remove the air flow baf fle. 4. Using a Philips screwdriver, unfasten the rear fan cover. 5. Lift and remove the rear fan cover. 6. Disconnect the fan connector from the circuit board. 3.6 re-installing top cover of ZX3 station 1.
COnfigurations 3.7 Removing a power supply module NOTE: If one of the power supply modules is WARNING: A failed power supply will removed, then the system will still operation be identified by an audible alarm. This with only one remaining power supply. alarm may vary based on your specific motherboard. 1. Using your fingers, twist to remove both screws from the rear top plate of the Power Supply module 2. Insert a finger into the handle and begin to pull the module from the station. 3.
COnfigurations 3.9 removing the lockable face plate cover 1. Using the provided key, turn to the right to unlock the face plate cover. 2. Using your fingers, twist to release the attachment screws on the left side of the face plate cover. 3. Pull the right side of the face plate cover away from the right support bracket. NOTE: The Lockable Face Plate Cover is an option available only to certain models. 4.
operations 4.0 Operations This section will provide information and assistance with the following topics: • Powering up the ZX3 Station • ZX3 Status Information & Indicators • Inserting & Removing Tranzpak2 Storage Modules 4.1 Powering on the ZX3 station 1. To power up the ZX3, press and hold (about 1 second) the Power Supply Switch at the center right side of the unit. 2. T he display may pos sibly indic ate items that require attention.
operations 4.3 Removing the Tranzpak2 storage Module 1. Slide the locking catch towards the right to allow the locking handle to spring open. 2. The locking handle will swing out. 3. Push the locking handle to the lef t. This will disconnect the TranzPak2 from the rear connector. 4. Gently but firmly begin to pull the TranzPak2 module out as it slides off the grounding contacts. 4.4 Inserting the tranzpak2 storage module 1. Raise the TranzPak2 module to the slot. and insert into the docking bay . 2.
Maintenance 5.0 Maintenance WARNING This section will provide information and assistance with the following topics: • Cleaning the ZX3 Server Be sure to turn off the power before you perform any maintenance on the server. • Replacing the ZX3 Air Filter 5.1 Cleaning the ZX3 Server Unplug the ZX3 server from the power outlet before cleaning. WARNING • To clean the surface of the ZX3, lightly dampen a soft, clean cloth with water or mild detergent and wipe the surface gently.
Troubleshooting 6.0 Troubleshooting the ZX3 Station This section will provide information and assistance with the following topics: • Troubleshooting Topics for the ZX3 Station • Frequently Asked Questions about the ZX3n Station Troubleshooting Topics In the event that the ZX3 Server experiences technical problems please refer to the following troubleshooting topics for potential resolution.
Customer Support 7.0 Customer support NOTE: If possible, stay by the computer. NOTE: More help, late-breaking news, and The Z Microsystems Technical Support details of the latest accesories for Z Micro Representative may wish to go through the products can be found on our website at : problem over the telephone. www.zmicro.com Technical Support If you are unable to correct the problem yourself, contact Z Microsystems at: Phone: Fax: Website: Email: (858) 831-7040 (858) 831-7001 www.zmicro.
Customer Support 7.1 Replacing Parts for the ZX3 Station If the Z Microsystems Technical Support Engineer determines that the product needs to be replaced, a Customer Service Representative will issue a Return Material Authorization (RMA) number. An RMA number is required to return a product to Z Microsystems, regardless of the reason for the return.
Appendix 8.0 Appendix 8.1 Technical Specifications for the ZX3 Station The ZX Series Servers are meticulously engineered to be adaptable and suited for an array of field operations and applications. These are standard ZX Series specifications. Other configurations may cause specifications to vary.
APPENDIX 8.2 Mechanical outlines FOR the ZX3 Station 8.2.1 ZX3 Station 17.15 NOTES: UNLESS OTHERWISE SPECIFIED 1. APPROXIMATE WEIGHT (WITHOUT HARD DRIVES): 33 LBS 17.15 NOTES: UNLESS OTHERWISE SPECIFIED 1. APPROXIMATE WEIGHT (WITHOUT HARD DRIVES): 33 LBS 20.64 20.64 FRONT ISO VIEW FRONT ISO VIEW 17.15 S OTHERWISE SPECIFIED E WEIGHT (WITHOUT HARD DRIVES): 33 LBS 5.20 2.84 5.20 20.00 0 0 .75 .75 17.0017.00 8.75 8.75 2.84 19.
APPENDIX MOUNTING HOLES (SLIDE RAILS NOT INSTALLED 0 .75 17.00 8.75 8.2.2 ZX3 Station - Rear view (AC/DC Power supply) 20.00 UNLESS OTHERWIS DIMENSIONS ARE TOLERANCES DECIMALS FRACTIONS XX = .01 1/32 XXX = .
Z Microsystems, Inc. 9820 Summers Ridge Road San Diego, CA 92121 Phone: (858) 831-7000 Fax: (858) 831-7001 Website: www.zmicro.com Copyright 2012 Z Microsystems, Inc. All Rights Reserved Z Microsystems, Inc. · 9820 Summers Ridge Road, San Diego, CA 92121 · T: 858.831.7000 · F: 858.831.7001 · www.zmicro.