User Guide
10-1-2013 3
Product specifi cations
• Vent pipes made of fl ame retardant Polypropylene material
(certifi ed for use fl ue gas in accordance with a European
standard DIN EN14471);
• Sealings are made of EPDM;
• Supports of aluminium;
• Supports of galvanized steel;
• Cox Geelen Pipe lubricant Chloride free;
• System diameters:
- Residential: 60mm (2”), 80mm (3”), 110mm (4”);
- Commercial: 125mm (5”), 160mm (6”), 200mm(8”);
• Shaftcover:
- Cover house is made from HDPE in the colour RAL9005
(Black), sizes 60mm (2”), 80mm (3”), 110mm (4”);
- Cover house is made from Stainless steel and aluminium
in the colour RAL9005 (Black), sizes 125mm (5”), 160mm
(6”), 200mm(8”);
- Termination pipe is made from UV-stabilized
Polypropylene material;
- Gasket is made of EPDM in the colour RAL9005 (Black);
- Bird mesh made of stainless steel;
• Concentric Roof termination:
- Internal vent pipe of fl ame retardant Polypropylene
material;
- External air pipe of galvanised steel sheet material in
the colour RAL9016, sizes Ø60/100mm (Ø2”/4”) and
Ø80/125mm (Ø3”/5”);
- External air pipe is made of galvanised steel sheet
material in the colour RAL9005, only size Ø110/160mm
(Ø4”/6”);
- Termination cap is made of UV-stabilized Polypropylene
material in the colour RAL9005, only Ø60/100mm
(Ø2”/4”) and Ø80/125mm (Ø3”/5”);
- Roof fl ashing is made of non-lead butyl fl ashing with
Polyethylene swivels;
- Rooffl ashing for fl at roof is made of aluminium;
• Single Wall Roof termination:
- Internal vent pipe of fl ame retardant Polypropylene
material;
- External pipe is made of galvanised steel sheet material in
the colour RAL9005, only size 125mm (5”), 160mm (6”),
200mm(8”);
• Concentric Wall termination:
- Internal vent pipe of fl ame retardant Polypropylene
material;
- External air pipe of galvanised steel sheet material in
the colour RAL9016, sizes Ø60/100mm (Ø2”/4”) and
Ø80/125mm (Ø3”/5”);
INTRODUCTION
Single wall CoxDENS
®
PPs is third party certifi ed to ULC-S636
standard for Class IIC rating (exhaust temperatures up to 110°C
(230°F) and CE EN14471. Certifi ed diameters are 60mm (2”),
80mm (3”), 110mm (4”), 125mm (5”), 160mm (6”) and 200mm (8”).
The following installation instructions are in accordance with the
requirements of section 4 of the ULC-S636 Standard.
Single wall CoxDENS
®
PPs is a vent system for type BH Gas-
Venting, for use with ANSI Category II and IV gas burning
appliances (condensing boilers) with a max fl ue gas temperature
of 110°C.
In addition, please refer to the appliance manufacturer’s
instructions for restrictions to the total vent length or height,
number of elbows that can be used, sizing of the vent or specifi cs
as to appliance connections before proceeding with the installation
of this product. Appliance manufacturer’s installation instructions
take precedence over this document.
INSTALLATION REQUIREMENTS
Installation and Annual servicing of the CoxDENS
®
PPs vent system
must be performed by a qualifi ed installer, service contractor or gas
supplier. The safe operation of a system is based on the use of parts
supplied by the manufacturer and the performance of the system
may be affected if the combination of these parts is not used in the
actual building construction.
Acceptance of the system is dependent upon full compliance with
the installation instructions.
Approvals/Codes
The installation has to conform to all relevant local, State, Provincial
or National codes. Single wall CoxDENS
®
PPs venting system is
approved for use under ULC-S636 Class II-C gas-fi red appliances
with a maximum fl ue gas temperature of 110°C (230°F). Cox Geelen
guarantees Single wall CoxDENS
®
PPs up to a maximum fl ue gas
temperature of 120°C (248°F).
All penetrations of fi re rated walls, fl oors, and ceilings must comply
with national and local building codes and regulations, and be
approved by the local regulatory authority and/or building inspectors.