ADDITIONAL PLUME MANAGEMENT KIT FOR VENT SYSTEM
Ø60MM (2”) AND Ø80MM (3”)
However the siting of the fl ue terminal often causes a pluming
problem. Especially when you have a wall terminal going straight
out through the wall. This problem can easily be solved by
repositioning the fl ue outlet. All the Cox Geelen ECONEXT
®
wall
terminals are provided standard with the special nozzle. With this
nozzle you have the possibility to mount a Plume Management
Kit within minutes. Just by removing the nozzle and easily clicking
the Plume Management Kit on the system in every desired angle.
Installation of the Plume Management Kit (PMK)
Remove the nozzle of the wall terminal with a screwdriver;
Mount the ECONEXT
®
PMK bend 90°. Its main advantage
is that you can install this bend into the necessary angle
by simply turning the outlet;
Connect the black vent pipe to the PMK bend;
Use two supports for the fi xation of the vent pipe to the
wall and secure every vent joint by a locking clamp;
Connect the 87° bend with bird mesh to the last mounted
vent pipe to fi nish the installation.
Terminations must be in accordance with the appliance
manufacturer’s instructions, local building code requirements,
CAN/CSA-B149.1 and CAN/CSA-B149.2.
MAINTENANCE
Cox Geelen recommends that gas appliances using CoxDENS
®
PPs venting should be checked once a year by a quali ed
installer.