VERTICAL TERMINATION THROUGH A MASONRY CHIMNEY
When using a masonry chimney as a passageway for CoxDENS
®
PPs, the chase must be structurally sound and free of any debris
or obstructions;
If only supported with a base support at the bottom
and a standard chimney cover at the top, the maximum
continuous vertical vent length for a rigid CoxDENS
®
PPs
vent system cannot exceed 164” (50m);
Multiple CoxDENS
®
PPs vent or air intake systems can be
installed into one chase;
Affi x Spacers onto each vent or air intake (offset them),
then pull or lower them individually or bundled into the
Chase;
CoxDENS
®
PPs expand slightly during normal operation.
CoxDENS
®
PPs pipe can expand upwards through the
Chimney Cover;
Install a Base Support bracket just below the entry point
into the chase;
Measuring from the base support, attach spacers at
intervals of 78” (2m) or less to the rigid pipe.
NOTE: Spacers serve to keep CoxDENS
®
PPs away from
rough surfaces and to avoid damage to the pipe during
installation or normal operation. They do not have a support
function. Attach Spacers to the pipe even if the chase is
larger than the reach of the Spacers.
Installation Manual CoxDENS
®
PPs
——›