User Guide

8 10-1-2013
q
w
e
r
t
CONDENSING SOLUTIONS
WALL PLATES
Concentric
B
3
C
9_x
Single wall
B
2
q
Flat roof termination
w
Wall termination
e
Flex vent termination
r
Rigid vent termination
t
Pitched roof termination
B
3
C
9_x
B
2
Wallplate B
2
Flue gas outlet only passes from the chimney shaft through the wall plate.
Flue pipe is not surrounded by air.
The combustion air is being taken from the installation room (separate
connection to the heating appliance).
Single pipe wall connection to the heating appliance.
Wallplate B
3
Flue outlet/air inlet have a
concentric connection but fl ue pipe
only passes from the chimney shaft
through the wall plate. The outer
pipe is blanked off to the chimney
shaft.
Flue pipe is surrounded by air and
therefore largely protected.
The combustion air is being taken
from the installation room via slots
in plate outer pipe.
Concentric connection to the
heating appliance.
Wallplate C
9_x
Flue outlet/air inlet are balanced
and concentric from the chimney
shaft.
Flue pipe is completely surrounded
by air and therefore fully protected.
Combustion air is being taken from
the ventilated chimney shaft.
Concentric connection to the
heating appliance.