User Guide

6 10-1-2013
Installation Manual CoxDENS
®
PPs Flex
o
INSERT SOCKET ADAPTER
Fit the bottom chimney bend on the
support. Make sure that the bend is
positioned centrally in the chimney.
A locking clamp is required at the Flex-
Rigid vent joint. Slide the locking clamp
over the male-end of the chimney bend
connector with the hook facing the joint.
Smear some of the enclosed lubricant (acid
free) on the o/d of the fl ex end connector.
The installation of the separate sections
will be connected by pushing the male-end
together with the female-end and snap the
hook over the gasket bead to secure the
two vent parts together.
‹—›Ð
ÚÐ
‹—›
Ú
Ð
u
PPs FLEX-LOWER CHIMNEY BEND ADAPTER
Fit the chimney bend connector to the
now open end of the fl exible pipe.
i
PPs CHIMNEY BEND
‹—›Ð
ÚÐ
In accordance with regulations,
we must advise that you ensure
the inner dimension of the
chimney does not exceed twice
the diameter of the fl exible pipe
(maximum 2x), in order to avoid
formation of a u-bend or air lock.
max. 30 m
m
a
x
.
4
5
°
ATTENTION
a
CHIMNEY TOP PROTRUSION OF FLEXIBLE PIPE
s
FITTING CHIMNEY COVER TO FLEXIBLE PIPE
Make sure that approx. 200 mm of the
exible pipe protrudes at the top of the
chimney.
Saw off excess exible pipe leaving the
correct length. Use a hand saw, cut in a
groove to keep cut square. Remove the
burr.
Please see expanded installation detail 11,
page 10, for the installation of the chimney
cover.
‹—›Ð
ÚÐ
‹—›
Ú
Ð
ATTENTION
Never use screws or adhesives for connections of this system. System is designed for use with clamps as stated above only.